8000-0748-01, Rev. C
SENSORVISION SYSTEMS 1
VIEW MANAGER 96
TOUCH TRACKER CONTROLLER
SENSORVISION SYSTEMS
Installing Touch Tracker
Controllers
Installation Kit (0351-0474-01):
Description Qty. Part No.
Mdlr cable assy, RJ45 .............
Screw, M2.9x9.5 .....................
Anchor, 4-8x.750 ....................
Screw, #8x1 ............................
Conn, 1x5pos .........................
Lug, 22-16AWG ......................
Cable, 3-cond..........................
Interconnect box......................
1
1
2
2
1
3
5m
1
6003-0047-01
5899-0004-102
2880-0083-01
2816-7634-44
2109-0254-04
2141-0002
6002-0024-01
0300-1000-01
WARNING—RISK OF ELECTRIC
SHOCK!
Disconnect AC power to the VM96 System
and External Interconnect Module before
starting to install this equipment. Failure to
do so could shock you and may damage
the VM96 system or attached devices.
CAUTION—ELECTROSTATIC
SENSITIVE DEVICE!
Follow proper handling procedures to
prevent component failure.
Figure 1. Attachment Concept
Planning the Touch Tracker
Network
The VM96 system supports a maximum of 8 Touch
Tracker controllers (controller). Controllers can attach
in a variety of configurations, but must follow all
SensorNet configuration and termination rules.
•
A network link's maximum length is 1350m (4430').
•
Each network link supports up to 32 devices and up
to 4 network branches.
•
Devices at each end point on a network link must be
terminated. Each network link supports up to 4
terminated devices.
•
The VM96 console provides 4 SensorNet links.
SensorNet J-Boxes provide additional links.
•
Each Touch Tracker controller attaches to the
network via an External Interconnect Module
(EIM), which provides the controller with power
and network termination.
See the Backbone and Star Network Guidelines on
the following page to determine the appropriate network
configuration for the controllers on your system.
Backbone Network Guidelines
The backbone network topology uses a single cable that
passes through each EIM, as shown in Figures 2 and 3.
In Figure 2, the EIMs at each end of the backbone must
be terminated. All other interconnect points, including
the console, are unterminated. In Figure 3, the console
and the last EIM are terminated. All other interconnect
points are unterminated.
Figure 2. Backbone Network Example #1
Figure 3. Backbone Network Example #2
External
Interconnect
Module
Power Supply
SensorNet Cable
Touch
Tracker
VM96
Console
TT
T - Terminated
EIMsEIMs
Touch Tracker Controllers
VM96
Console
T
T
T - Terminated
EIMs
SensorNet Cable
EIMs
Touch Tracker Controllers
VM96
Console
SensorNet Cable