ADACSNET USB CONTROL MODULE 8200-0310-01, REV. C
INSTALLATION GUIDE
2 of 6
Software Installation for Non-
Intellex Systems
Note: This procedure applies to systems using
Microsoft
®
Windows
®
2000 or Windows
®
XP
operating systems.
If you are not connecting the ADACSNET module
to an Intellex system, special drivers and utilities
software must be downloaded to your personal
computer that enable its use.
USB Control Module Software Utilities User Guide,
8200-0310-02, explains how to download this
software. To obtain this guide:
1. On the internet, go to
http://americandynamics.net/home/default.aspx,
and click Support.
2. In the dropdown menu, click Support
Documents, and then click Manual Index.
3. Click SpeedDomes and Accessories, and
then scroll down and click USB Control Module
Software Utilities User Guide.
4. Follow the instructions on the screen to
download the user guide PDF file.
SensorNet Rules and
Network Types
The SensorNet communication protocol allows the
host computer and camera domes to exchange
data along a cable network (star, daisy chain, or
backbone).
SensorNet Rules
A star network cannot have more than four
branches, one line termination per branch.
A backbone network has a termination at each
end of the line.
A SensorNet line cannot have more than 32
network-compatible devices.
A network cannot have more than four
repeaters in the path of any two camera domes.
A SensorNet line or branch cannot exceed 1km
(3300ft). Use signal repeaters only when
exceeding the maximum distance or noise is an
issue.
Signal levels for SensorNet-compatible devices
are from 0.3–5V (1–5V is recommended).
Network Types
Star Network
The star network allows you to relocate devices.
However, this network is not recommended in high
noise environments because the extra terminations
required will lower the signal to noise ratio.
A separate cable line (branch) runs from the USB
module to each device. Limit the branches to four.
The example below shows the USB module as the
hub of a star network. The module is not
terminated.
Black box = USB module, T = Terminated
Daisy-Chain/Backbone Network
Use a daisy chain network if the cable is to be
short, extended in the future, or when USB module
and camera domes are in the same room. In a
daisy chain, a separate cable connects every two
adjacent devices along the chain. Daisy chaining
makes it easy to add devices by extending the
network from a nearby device. The USB module
can connect anywhere along the cable.
Use a backbone network if the cable is to be long
and permanent. This network type operates the
same as the daisy chain, but uncut wires may be
more conductive and reliable. In a backbone, a
single cable is used. Along the cable, 2.5cm (1in)
sections are stripped, bent, and connected to each
remote device. The USB module can connect
anywhere along cable.
The example below shows the USB module at end
of a daisy chain or backbone network. The module
and the last camera dome in the chain are
terminated.
Black box = USB module, T = Terminated