Alarms, Areas and Home Settings 4-5
• If you are finished making changes, press and hold Iris Close, then press Focus
Near or Focus Far to save your changes and exit the utility.
2
• If you want to make changes to other settings, use the Tilt control to move the
highlight bar to Exit, then press Focus Far. The Dome Configuration Menu
appears. Continue with What To Do Next on page 4-13.
Configuring Normal Input States
IMPORTANT
Certain controllers allow the normal input states for domes to be specified at
the controller. These controllers include VM96, AD matrices with AD2083-
02A code units or AD168 matrix with AD168CCM or AD2083-02A code
unit. Do not use both the dome configuration utility and the controller to
assign the normal input states. Use only the dome configuration utility or
the controller to the assign the normal input states.
When Configure Normal States is selected from the Alarm/Areas/Home screen, the
following is displayed:
CONFIGURE NORMAL STATES
EXIT
INPUT NO.
NORMAL STATE
OPEN
1
OPEN
2
CLOSED
3
OPEN4
Figure Chapter 4 -3: Configure Normal States Screen
Use this screen to assign open or closed as the normal state for the dome inputs. When an
input state changes from normal to abnormal and an internal alarm action is associated with
the input, the alarm is triggered. The normal state is used by both internal alarms and
controller defined alarms.
2
This command is not supported with Manchester.
Highlight Bar:
Move with Tilt