Intellex RMS Digital Video Management System
Alarm Operation 185
Generated Alarms
At any time, the operator can flag specific activity as an alarm event, even if the
activity does not trigger a filter or trip an alarm. For more information on generating
alarms, see Creating an Activity Log on page 55.
When the operator generates an alarm:
1. The unit energizes the alarm output associated with the camera.
2. The unit records images from the alarm camera at the alarm record rate and
quality setting.
3. The unit adds the alarm camera to the alarm group and records its images more
often than nonalarm cameras (see Alarm Groups ).
4. The unit lights the Alarms indicator as soon as the alarm is cleared.
5. The unit flags the video segment in the image database with the name Gen. Alarm.
6. If the Pre-Alarm Duration option is selected, the unit saves the pre-alarm images to
the image database (see Use Custom Schedule on page 76).
7. If the Alarm Message Display option is selected:
a. If the camera is not currently displayed or is displayed in the camera
sequencing window, the unit switches the live display monitor to the 4x4
format and overrides the display settings for the duration of the alarm (see
Display Option on page 139).
b. The unit displays ALARM over the camera image.
c. If the Latch Messages option is selected, the unit enables the Clear Latched
button on the Utility Options screen (see Utility Options on page 53).
d. The unit suspends camera sequencing on the live display monitor.
8. If the Unit Alarm Out option is selected, the unit energizes alarm output 16.
The unit remains in the alarm state until ALL of the following occur:
a. All alarms, including mechanical, are released.
b. The Duration time elapses.
Once the unit exits the alarm state, it returns to the previous display mode, record
mode and quality settings.
If the Latch Messages option is selected, the unit displays the alarm message until
the Clear Latched button on the Utility Options screen is clicked (see Utility Options
on page 53).